<Update label="October 19, 2026" description="PDF reports for parameterized models, the data behind every plot, and dashboards that stay yours">
  ## PDF reports for parameterized models

  A parameterized model's page has a **Report** button that downloads a PDF of the model as
  it stands. Each function-valued parameter is plotted against its input (stoichiometry,
  state of charge, electrolyte concentration or temperature), with one curve at each of 0,
  10, 25, 35 and 45 °C where temperature is an input. Where possible it is also written out
  as an equation, with a legend giving each referenced parameter's name and value. A
  parameter that can't be plotted is listed in a **Not plotted** table with the reason.
  Scalar parameters are tabulated in the same
  sections as the model's parameter tabs, after a cover page listing the model type,
  thermal and ageing options, and description.

  ## See and export the data behind a plot

  Dashboard plots, and plots in the measurement plot drawer, have a **View source data**
  menu item. It opens one table of the data the plot is drawn from — with the measurement,
  cell and specification names alongside the values where the plot reads them — and the same table downloads as CSV.
  Values the plot calculates while drawing are not included, and the dialog says so.

  ## Dashboards stay the way their creator left them

  Only the person who created a dashboard can edit or delete it, its plots, or its agent
  drafts. Everyone else with access can still view it and change plot inputs for
  themselves (never saved). Anyone whose role can create dashboards (Project Admins and
  Contributors) can also **make their own version** of the whole dashboard, or **copy a
  plot** to a dashboard of their own. A duplicated dashboard shows where it came from
  ("Copied from X on 2026-10-11 15:52"). Trying to change someone else's dashboard explains how to get an editable copy.

  ## Repair a file whose time runs backwards

  A raw file that fails the time-ordering check no longer leaves only **Accept and
  continue** or **Discard this file**. The review now shows the offending rows and offers just the repairs that fit
  the problem, recommended first: rebuild a continuous clock (when a per-step clock was
  exported instead of total elapsed time), sort rows by time, drop the out-of-order rows, or
  separate identical timestamps. A repair that doesn't restore ordering is reported as still
  needing input rather than marked fixed.

  <AccordionGroup>
    <Accordion title="Studio">
      **Improvements**

      * **Choose the agent's model.** A picker under the chat input switches between Opus 5.5
        (the default), Sonnet 5.5 and Haiku 5.5, and your browser remembers the choice.
      * **Analysis plots read cleanly when a test repeats set-points.** Points are drawn in x
        order as markers, with a line through each set-point's mean, so a rate table run twice
        reads as one line instead of a sawtooth. This applies in the plot drawer, dashboards
        and the analysis page.
      * **The protocol generator is faster and fails less often.** It no longer gets stuck
        re-reading the same reference material until it gives up.

      **Fixes**

      * **An older export of a running test no longer closes it.** A manually uploaded file
        whose data ended more than two days ago marked the test as finished, so the next,
        fuller export was refused as not fitting. Runs already closed this way are unchanged.
      * **Reported metrics no longer show a misleading number when a threshold is never
        reached.** A metric such as "Charge time (10–80% SOC)" on a charge that stalls before
        80% now shows no value.
      * **Stacked dashboard plots** put the x axis under the bottom row instead of the top.
        Plots already on a dashboard pick this up when they are re-sent or edited.
      * **Paging past the end of a list**, for example after a filter shrinks it, returns an
        empty page on the pipelines list and most others, instead of a server error.
    </Accordion>

    <Accordion title="Pipeline">
      The metric examples below use the `ionworkspipeline` Python classes; in a pipeline config
      the same metrics are written as dicts, e.g. `{"type": "Crossing", ...}`.

      **Improvements**

      * **A metric can span several steps.** Any metric's `step` accepts a list of consecutive
        steps, read as one, e.g. `Minimum("Negative electrode potential [V]", step=[2, 3, 4])`.
        Gaps, repeats and descending lists are rejected with a message pointing to
        `ComposedMetric`.
      * **New `Crossing` metric**, `Crossing(variable, crossing_variable, value, step)`, reads
        `variable` at each point where `crossing_variable` crosses `value`. `SOC` and `Voltage` are now
        special cases of it, with their configs unchanged.
      * **Crossing thresholds can be metrics.** `value` accepts a metric evaluated on the whole
        solution, so a threshold can depend on an earlier step, e.g. the time for throughput to
        go from 10% to 80% of a step-0 capacity.
      * **`by_cycle(step={cycle: step})`** reads a different step in each cycle, for a quantity
        logged at different positions in different cycles.
      * **`RelativeTime` validates as a metric config**, on its own, as a threshold, and in
        design optimizations.
      * **`DirectEntry` references must be in the pipeline's project.** A `pipeline_id` or
        `cell_spec_id` from another project is refused with a permissions error that says how
        to fix it.

      **Fixes**

      * **Pipeline calculations that read a stored measurement** (for example an OCP
        interpolant from a GITT measurement) no longer fail with an authentication error.
      * `CycleAgeing` no longer saves only a threshold's cycles for a crossing searched over
        the whole solve; an unsliced crossing with a cycle-sliced threshold is now rejected.
      * A missing variable in `SOC` now gives a `UserConfigurationError` that names it, rather
        than a bare `KeyError`.
    </Accordion>

    <Accordion title="Protocol Simulator">
      **Fixes**

      * **Arbin `LS_CHAN_*` capacity and energy** are read as the cumulative channel counters
        at the end of the previous step, matching the cycler. Protocols that read them after
        several steps without a counter reset (e.g. sizing GITT pulses from a two-part
        discharge) had used only the last step. Arbin energy counters now accumulate too.
    </Accordion>